Mostrar el registro sencillo del ítem
Variación en el diagnóstico por ecografía doppler de insuficiencia valvular venosa de miembros inferiores, de pie y semisentado, utilizando las maniobras de Valsalva y compresión distal
dc.contributor.author | Sáenz Prieto, Wilson L | spa |
dc.contributor.author | Evan Knepper, Juan David | spa |
dc.contributor.author | Mantilla Suárez, Juan Carlos | spa |
dc.contributor.author | Lubinus Badillo, Federico Guillermo | spa |
dc.contributor.author | Rey Serrano, Juan José | spa |
dc.date.accessioned | 2020-10-27T14:21:15Z | |
dc.date.available | 2020-10-27T14:21:15Z | |
dc.date.issued | 2007-04-15 | |
dc.identifier.issn | 2382-4603 | |
dc.identifier.issn | 0123-7047 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12749/10358 | |
dc.description.abstract | ResumenObjetivo: Determinar las diferencias en el diagnostico de insuficiencia venosa por ecografÌa doppler color en dos posiciones (semisentado y de pie) utilizando maniobras Valsalva y compresión distal. MetodologÍa: Se estudiaron 98 pacientes con insuÞciencia venosa grado 1 a 3. En todos los pacientes se evaluó la presencia de reßujo estando semisentado más Valsalva, semisentado y compresión distal, de pie más Valsalva, y de pie con compresión distal. Resultados: Hay diferencias en los resultados entre las tÈcnicasevaluadas. Para compromiso proximal hay mayor frecuencia de reßujo en posición semisentado más Valsalva; para compromiso medio las pruebas son similares: para compromiso distal, hay mayor frecuencia de reßujo con el paciente de pie más compresión distal. Conclusión: Dependiendo del grupo venoso a evaluar, es necesario adecuar la técnica de evaluación con ultrasonido doppler color utilizada.[Sáenz WL, Evan JD, Mantilla JC, Lubinus FG, Rey JJ. Variación en el diagnóstico por ecografÍa doppler de insuÞciencia valvular venosa de miembros inferiores, de pie y semisentados utilizando las maniobras de valsalva y compresión distal. MedUNAB 2007; 10:13-18].Palabras clave: Insuficiencia venosa, ecogafÌa doppler color, cirugÍa vascular. | spa |
dc.format.mimetype | application/pdf | spa |
dc.language.iso | spa | spa |
dc.publisher | Universidad Autónoma de Bucaramanga UNAB | |
dc.relation | https://revistas.unab.edu.co/index.php/medunab/article/view/121/107 | |
dc.relation.uri | https://revistas.unab.edu.co/index.php/medunab/article/view/121 | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/2.5/co/ | |
dc.source | MedUNAB; Vol. 10 Núm. 1 (2007): Sobrepeso, Histeroscopía, Tamizaje de mama; 13-18 | |
dc.subject | Ciencias de la salud | |
dc.subject | Medicina | |
dc.subject | Ciencias médicas | |
dc.subject | Ciencias biomédicas | |
dc.subject | Ciencias de la vida | |
dc.subject | Innovaciones en salud | |
dc.subject | Investigaciones | |
dc.title | Variación en el diagnóstico por ecografía doppler de insuficiencia valvular venosa de miembros inferiores, de pie y semisentado, utilizando las maniobras de Valsalva y compresión distal | |
dc.title.translated | Variation in the diagnosis by Doppler ultrasound of venous valve insufficiency of the lower limbs, standing and semi-sitting, using the Valsalva maneuvers and distal compression | eng |
dc.type.driver | info:eu-repo/semantics/article | |
dc.type.local | Artículo | spa |
dc.type.coar | http://purl.org/coar/resource_type/c_6501 | |
dc.subject.keywords | Health Sciences | eng |
dc.subject.keywords | Medicine | eng |
dc.subject.keywords | Medical Sciences | eng |
dc.subject.keywords | Biomedical Sciences | eng |
dc.subject.keywords | Life Sciences | eng |
dc.subject.keywords | Innovations in health | eng |
dc.subject.keywords | Research | eng |
dc.subject.keywords | Doppler ultrasound | eng |
dc.subject.keywords | Lower limbs | eng |
dc.subject.keywords | Venous insufficiency | eng |
dc.identifier.instname | instname:Universidad Autónoma de Bucaramanga UNAB | spa |
dc.type.hasversion | Info:eu-repo/semantics/publishedVersion | |
dc.type.hasversion | info:eu-repo/semantics/acceptedVersion | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | spa |
dc.relation.references | 1. Giraldo M, Serna J. Fundamentos de medicina. Vascular periférico. Fisiología del sistema venoso. Medellín, CIB, 3 ed, 2001. | |
dc.relation.references | 2. Jantet G. Chronic venous insuffi ciency: worldwide results of the RELIEF study. Refl ux assEssment and quaLity of lIfe improvEment with micronized Flavonoids. Angiology 2002; 53:245-56. | |
dc.relation.references | 3. Nicolaides AN, Cardiovascular Disease Educational and Research Trust, European Society of Vascular Surgery, The International Angiology Scientifi c Activity Congress Organization, International Union of Angiology, Union Internationale de Phlebologie at the Abbaye des Vaux de Cernay. Investigation of chronic venous insuffi ciency: A consensus statement (France, March 5-9, 1997). Circulation 2000; 102:26-63. | |
dc.relation.references | 4. Masuda. EM, Kistner RL, Eklof B. Prospective study of duplex scanning for venous reflux: Comparison of Valsalva and pneumatic cuff techniques in the reverse Trenddelenburg and standing positions. J Vasc Surg 1994; 20:711-20. | |
dc.relation.references | 5. van Bemmelen PS, Bedford G, Beach K, Stranddness DE Jr. Quantitative segmental evaluation of venous valvular refl ux with duplex ultrasound scanning. J Vasc Surg 1989; 10:425-31. | |
dc.relation.references | 6. Foldes MS, Blackburn MC, Holgan J. Standiing versus supine positioning in venous refl ux evaluation. J Vasc Tech 1991; 15:321-4. | |
dc.relation.references | 7. Masuda EM, Kistner RL. Prospective comparison of duplex scanning and descending venography in the assessment of venous insuffi ciency. Am J Surg 1992; 164:254-9. | |
dc.relation.references | 8. Haenen JH, Van Langen H, Janssen MCH, Wollersheim H, van Hot MH, Wim NJC, et al. Venous duplex scanning of the leg: range, variability and reproducibility. Clin Sci 2000; 98:449-54 | |
dc.relation.references | 8. Haenen JH, Van Langen H, Janssen MCH, Wollersheim H, van Hot MH, Wim NJC, et al. Venous duplex scanning of the leg: range, variability and reproducibility. Clin Sci 2000; 98:449-54 | |
dc.relation.references | 9. Markell A, Heissner M, Manzo R, Bergelin R, Strandness E. A comparison of the cuff defl ation method with Valsalva’s maneuver and limb compression in detecting venous valvular refl ux. Arch Surg 1994; 129:701-5. | |
dc.relation.references | 10. Lagattolla NR, Donald A, Lockhart S, Burnand KG. Retrograde fl ow in the deep veins of subjects with normal venous function. Phlebology 2002; 17:19-28 | |
dc.relation.references | 11. Foldes MS, Blackburn MC, Hogan J. Standing versus supine positioning in venous refl ux evaluation. J Vasc Tech 1991; 15:321-4. | |
dc.relation.references | 12. Nash R. Varicose veins. Br Med J 2000; 320:1391- | |
dc.relation.references | 13. Jeanneret KH, Aschwanden L, Bollinger A, Hoffmann U, Jager K. Physiological refl ux and venous diameter change in the proximal lower limb veins during a standardized Valsalva manoeuvre. Permanence J 2003; 7:54-60 | |
dc.relation.references | 14. Szendro G, Nicolaides AN, Zukowski AJ, Christopoulos D, Malouf GM, Christodoulou C, et al. Duplex scanning in the assessment of deep venous incompetence. J Vasc Surg 1986; 4:237-42 | |
dc.relation.references | 15. Belcaro G, Nicolaides AN, Ricci A, Dugall M, Errichi BM, Vasdekis S, et al. Endovascular sclerotherapy, surgery and surgery plus sclerotherapyin superfi cial venous incompetence: a randomized, 10- year follow up trial –fi nal results. Angiology 2000; 51:529-34 | |
dc.contributor.cvlac | Mantilla Súarez, Juan Carlos [0001482827] | |
dc.contributor.cvlac | Lubinus Badillo, Federico Guillermo [0001475552] | |
dc.contributor.cvlac | Rey Serrano, Juan José [0001475552] | |
dc.contributor.googlescholar | Rey Serrano, Juan José [es&oi=ao] | |
dc.contributor.orcid | Mantilla Suárez, Juan Carlos [0000-0001-8377-9571] | |
dc.contributor.orcid | Lubinus Badillo, Federico Guillermo [0000-0003-1741-7016] | |
dc.contributor.orcid | Rey Serrano, Juan José [0000-0002-6946-2444] | |
dc.contributor.scopus | Rey Serrano, Juan José [54793298100] | |
dc.identifier.repourl | repourl:https://repository.unab.edu.co | |
dc.description.abstractenglish | Objectives: To determine differences in diagnosis of valvular insuffi ciency by color doppler ultrasonography in standing or semi-Fowler position and Valsalva maneuver or distal compression. Methodology: 98 patients with 1-3 degreee valvular insuffi ciency were studied All of thew were evaluated by doppler ultrasonography in booth positions and maneuvers. Results: There were differences between the different techniques. In upper segments, a higher frequency of refl ux was found with semi-Fowler plus Valsalva´s maneuver; in intermediate segments there were similar refl ux prevalences using both positions; and, in lower segments, there was more refl ux using standing position plus Valsalva´s maneuver. Conclusion. Depending on the venous group to evaluate, it is necessary to adapt the evaluation technique used with Doppler ultrasound color test. | eng |
dc.subject.proposal | Ecografía doppler | spa |
dc.subject.proposal | Miembros inferiores | spa |
dc.subject.proposal | Insuficiencia venosa | spa |
dc.type.redcol | http://purl.org/redcol/resource_type/ART | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 2.5 Colombia | * |
dc.contributor.researchgroup | Grupo de Investigaciones Clínicas | spa |
dc.contributor.researchgroup | Observatorio de Salud Pública de Santander | spa |
dc.contributor.researchgroup | Grupo de Investigaciones Clínicas | spa |